What Does a Home Inspector Check on a Deck?

Under the InterNACHI Standards of Practice, a home inspector inspects "porches, patios, decks, balconies and carports," the "stairs, steps, stoops, stairways and ramps," and the "railings, guards and handrails," and reports "any improper spacing between intermediate balusters, spindles and rails." The same standards describe a home inspection as "a non-invasive, visual examination of the accessible areas of a residential property," so the deck check covers what can be seen and reached. For how a deck should be built, the American Wood Council's DCA 6 guide, in its edition based on the 2015 IRC, sets out details such as 6x6 minimum posts, corrosion-resistant flashing at the ledger and a guard on any deck more than 30 inches above grade.
As of October 2026, Pennsylvania's Uniform Construction Code has used the 2021 International Residential Code since January 1, 2026, and the state's IRC amendment list in 34 Pa. Code 403.21(a)(7) does not amend the deck section, R507. Even so, 34 Pa. Code 403.62(c)(8) says no permit is required for "an uncovered deck where the floor of the deck is no more than 30 inches above grade," and the City of Pittsburgh gives uncovered decks 30 inches or less zoning review only. A low deck on a house you are buying may have no building permit record behind it. This post covers what the inspection includes, ledgers, lateral load connections, posts and footings, guards and stairs, permits and what a visual check cannot see.

What Does a Home Inspection Cover on a Deck?
The deck falls under the exterior section of the InterNACHI Standards of Practice, alongside stairs, steps, stoops and railings. Baluster spacing is one of the conditions the standards name for the report.
A deck ledger is the board that fastens a deck to the house, and the North American Deck and Railing Association (NADRA) describes it as the place "where the deck attaches to the house and a common source of deck failure."
The standards also set limits. The inspector is not required to "inspect items that are not visible or readily accessible from the ground, including window and door flashing." Finishes can hide things too. InterNACHI's illustrated deck inspection article says, "Paint can hide decay from an inspector and so should be noted in the report."
NADRA's checklist suggests a professional such as a deck builder or a home inspector for a deck evaluation, and notes that checking a deck with its list does not mean the deck is code compliant. For the rest of the exterior review, see what inspectors look for on exterior and site conditions in Allegheny County.
How Should a Deck Ledger Be Attached to the House?
AWC's DCA 6 guide, in the edition based on the 2015 IRC, says "Attachments are made to the house band joist," and it limits what can hold the ledger there: "Only those fasteners noted below are permitted. LEAD ANCHORS ARE PROHIBITED." Lag screws and through-bolts on its list are 1/2 inch in diameter.
DCA 6 also rules out some surfaces. Its prohibited list includes "Attachments to exterior veneers (brick, masonry, stone), hollow masonry," and it repeats the point for brick in capital letters. It also says "House siding or the exterior finish system must be removed prior to installation of the ledger board," and "Approved corrosion resistant flashing is required at any ledger board connection to a wall of wood framed construction."
NADRA's consumer checklist adds three plain checks:
"The ledger board should not be fastened with only nails."
"If a fastener appears rusted or corroded, consider replacing it," and "A corroded fastener can cause deterioration in surrounding wood."
"Be certain the flashing is sound and firmly in place."
InterNACHI's deck article says through-bolts should be at least 1/2 inch in diameter with washers at the bolt head and nut, and that "The ledger board should always be flashed even when the home or building has a protective roof overhang."
What Is a Lateral Load Connection on a Deck?
A lateral load connection is hardware that helps a deck resist lateral, or sideways, forces where it meets the house. DCA 6 applies to "single-level residential wood decks that are attached to the house to resist lateral forces."
The guide's requirement is specific. "Hold-down tension devices shall be provided in not less than two locations within two feet of the edge of the deck," and each "shall have an allowable stress design capacity of not less than 1,500 lb." DCA 6 shows the connection details in its figures for ledger and non-ledger decks.
Whether an inspector can see these devices depends on access below the deck. If the underside is enclosed or blocked by storage, ask the inspector to note what could not be viewed.
What Should Posts, Joists and Footings Look Like?
DCA 6 sets these minimums:
Part | What AWC's DCA 6 guide says |
Posts | 6x6 nominal or larger, with height limits in its Table 4; 8x8 posts limited to 14 feet |
Joist hangers | Depth of at least 60% of the ledger or beam depth |
Footings | Bear on undisturbed soil at least 12 inches below the undisturbed ground surface |
The 2021 IRC deck footing section, R507.3, also puts footings at least 12 inches below undisturbed ground and calls for frost-protected footings when a deck is attached to a frost-protected structure, with exceptions for certain free-standing decks. Footing depth is underground, so a visual inspection does not measure it.
Wood condition is easier to judge. NADRA suggests probing with "a tool like an ice pick or a screwdriver." If the tool easily goes in 1/4 to 1/2 inch, a sliver breaks off without splinters, or the wood is soft and spongy, NADRA says "decay may be present." It also says, "The deck or stairs should appear even without sagging and should not sway or move when tested."
Insect damage to wood has its own inspection; read about wood destroying insect inspections in PA and why termite checks matter, and about the exterior structural elements a structural inspection looks at.
What Are the Guard, Railing and Stair Details on a Deck?
DCA 6 says decks more than 30 inches above grade are required to have a guard, and it calls for guard post hold-down anchors with a minimum allowable tension load of 1,800 pounds for a guard up to 36 inches high.
Other sources fill in height and spacing:
Guard height. InterNACHI's deck article puts residential guardrails "at least 36 inches from the deck surface."
Baluster spacing. The same article says infill "should not permit a 4-inch sphere to pass through."
Strength. A 2017 AWC article in STRUCTURE magazine calls for guardrails "capable of resisting a minimum concentrated live load of 200 pounds applied in any direction."
Open stairs. NADRA says that if the area behind the stair treads is open, the opening should be no more than 4 inches high.
Pennsylvania changes the IRC's stair dimensions. Its amendments in 34 Pa. Code 403.21(a)(7) set stair risers at 8 1/4 inches maximum and treads at 9 inches minimum. The municipality's code office can confirm how those apply to a given deck stair.
Does a Deck Need a Permit in Pennsylvania?
Not if it fits the state's exemption. Under 34 Pa. Code 403.62(c)(8), an uncovered deck with its floor no more than 30 inches above grade needs no UCC permit, as long as the work does not violate a law or ordinance. The Pennsylvania text sets no size or attachment condition.
That is broader than the 2021 IRC model exemption, which is limited to decks of 200 square feet or less, not more than 30 inches above grade, not attached to the house and not serving the required exit door. Pennsylvania uses its own 403.62 list instead.
In the City of Pittsburgh, uncovered decks 30 inches or less get zoning review only, and the city says exempt work must still meet its Zoning Code. A deck that is higher or covered falls outside the state exemption, so a buyer can ask the municipality's code office whether a permit was issued for it.
Once the report and any permit answers are in, this guide to which repairs buyers should request after an inspection covers how to prioritize what to raise with the seller.
FAQ
Can a deck ledger be nailed to the house?
NADRA says the ledger "should not be fastened with only nails." AWC's DCA 6 guide permits only the fasteners it lists, such as 1/2 inch lag screws or through-bolts, and prohibits lead anchors.
Can a deck ledger be attached to brick?
Not to brick veneer, under DCA 6. The guide prohibits ledger attachment to exterior veneers such as brick, masonry or stone, and to hollow masonry.
How tall does a deck railing need to be?
At least 36 inches from the deck surface for residential guardrails, according to InterNACHI's deck article. DCA 6 requires a guard on decks more than 30 inches above grade. The local code office can confirm what applies to a specific deck.
How far apart can deck balusters be?
InterNACHI's deck article says guard infill should not let a 4-inch sphere pass through. Improper baluster spacing is one of the conditions the InterNACHI Standards of Practice name for the inspection report.
Does a deck need a permit in Pittsburgh?
An uncovered deck 30 inches or less above grade gets zoning review only in the City of Pittsburgh, and it must still meet the City Zoning Code. Higher or covered decks fall outside Pennsylvania's permit exemption, so check with the city before building or buying.
How can you tell if deck wood is rotting?
NADRA suggests pressing an ice pick or screwdriver into the wood. If it easily goes in 1/4 to 1/2 inch, a sliver breaks off without splinters, or the wood feels soft and spongy, decay may be present.
Deck Checks in a First Class Home Inspections Single Family Inspection
First Class Home Inspections, a Pittsburgh, PA home inspection company with InterNACHI Certified Professional Inspector certification, lists porches and decks among the items in its Single Family Home Inspection, along with the exterior, the roof and the foundation. Its services page covers porch and deck inspection as part of a home inspection, along with Wood-Destroying Insect (WDI) inspections on the NPMA-33 form for FHA, VA and USDA loans. If repairs follow, the company refers clients to a vetted network of contractors that includes carpenters, and its follow-up inspections can verify contractor corrections.